This section contains information load location, plus a grounding flag, the memo and the tags. Each load must have an entry in this section. The first line in the section must say: [LOADEX DATA]. This is followed by the data described below. A blank line ends the section.
1. Bus Name: Name of the bus to which the load is attached, enclosed in quotation marks.
2. Base kV: Nominal kV of the bus.
3. Ground flag:.0 if not grounded; 1 if grounded.
4. Memo: Comments with a maximum of 512 characters. Any alpha-numeric characters can be used, except for the string delimiter (single or double quotation mark). The comment text is enclosed in quotation marks.
5. Tags: Tag string with a maximum of 512 characters. Tags in string are separated by semicolon. Any alpha-numeric characters can be used, except for the string delimiter (single or double quotation mark). The tag string is enclosed in quotation marks.
6. UDF: User-defined data fields. Enter the list of user defined field values as a tab delimited text string enclosed in single quotes.
An example LOADEX data section is shown below.
[LOADEX DATA]
'WASHINGTON' 33= 1 'Load Memo text' 'CCTest\c'
'ALASKA' 33= 0 '' ''
'CALIFORNIA' 33= 0 '' ''
'CLAYTOR' 132= 0 '' ''