Index

A

Acquire Graphics from Another File i

Add File i

ADX text data file i

ANAFAS Format

compatibility with i

create change file i

export to i

read change file i

ANAREDE Format

export to i

Annotation in Curves Window

add i

remove i

Annotation in Distance Relay Window

add i

remove i

Annotation in Main Window

add i

as bookmark i

attach to objects i

delete i

detach from objects i

find i

hide or show i

highlight attached object i

Anomalies Checking i

ANSI X/R Ratio See also X/R Ratio

definition and computation i

Arc Flash Hazard Calculator IEEE 1584-2011 i

Arc Flash Hazard Calculator IEEE 1584-2018 i

Area

data in text data file i

renumber i

show area number on one-line i

show tie lines on one-line i

Area Data Modification i

Area of a Bus

change i

ASEN Relay Database Setting Data

import from i

ASPEN CIM Module i

ASPEN CIM Profile i

ASPEN CIM tool i

ASPEN DistriView

updating substation impedance i

B

Backup File i

Base MVA

system i

Batch Fault Simulation i

BESS i

Binary Data File i

automatic backup i

close i

create new i

open i

save i

save as i

save copy for new study date i

Boundary Equivalent

creating i

ID prefix for fictitious branches and generators i

special color code for fictitious elements i

Branch Names on One-Line i

Breaker

check anomalies i

checking rating i

data in text data file i

delete all i

dialog box and data i

export data i

IEC rated i

interrupting time i

no-ac-decay ratio i

protected equipment i

symmetrical current rated i

total-current rated i

Breaker Failure Condition i

Breaker Interrupting Time i

Breaker Opening Time

definition i

Breaker Rating

ANSI/IEEE-rated breakers i

higher interrupting rating for 1LG faults i

IEC-rated breakers i

non-ac decay ratio override i

Breaker Rating Module i

Build 1-Line Diagram i

Bus

adjust symbol length i

change area and zone in region i

change nominal kV i

change symbol i

data used for text file i

delete i

description of faults i

dialog box and data i

find by name i

find by number i

go to end bus i

insert tap bus into a line i

merge i

model i

place i

place using state-plane coordinates i

remove tap bus from a line i

show and hide i

show or hide ID i

split i

Bus Fault Summary i

Bus Numbers

hide or show i

Bus Selector i

Buses

sort by name or number i

Bus-List File Format i

C

Capacitor and Reactor See Shunt

CAPE i

Case Builder i

Case builder file i

Case Comparison Program i

CBX file See Case builder file

Change File i

comments i

Change from Line to Series Capacitor/Reactor i

Change Nominal kV i

Change T to 3-Winding Transformer i

Checking Breaker Rating i

Checking Coordination of Reclosers with Overcurrent Relays i

Checking Equipment Status Against Study Date i

Checking Instantaneous Settings of Overcurrent Relays i

Checking Network Anomalies i

Checking Pickup of Overcurrent Relays i

Checking Relay Coordination using Primary-Backup Pairs i

Checking Relay Loadability i

Checking Settings of Overcurrent and Distance Relays i

CIM standards IEC 61968 and 61970 i

Circuit Breaker See Breaker

Circuit Breaker Rating See Breaker Rating

Classical Fault i

Clear screen of fault results and other text labels i

Color Code

by voltage class i

colors for boundary equipvalent and certain tagged equipment i

Combined OneLiner and Power Flow Executable i

Command Editor

close i

differences between v10 and v12 i

edit i

print i

run commands i

save i

save file as i

Command Editor Window i

Command File i

bus, line-end, line-out commands i

fault all buses command i

intermediate faults command i

output coverage i

Command Line Parameters i

Communication Assisted Relay Schemes See Logic Schemes

Compare Files i

Complex X/R Ratio

definition i

COMTRADE Formatted Relay Test File i

COMTRADE standard i

Conductor Damage Curve

add i

edit parameters of i

Converter-Interfaced Resource

dialog box and data i

for modeling STATCOM i

modeled with no MW injection i

QandA i

Coordinating Time Interval

definition i

Copy to Clipboard

graphical data from DS Relays Window i

graphical data from OC Curves Window i

network and relay data in region i

network data i

one-line graphics in a region i

relay data i

text from TTY Window i

CTI i

Curve Collection i

open i

save DS Relays Window objects i

save OC Curves Window objects i

Curve Selector i

Curves Window

add accuracy boundary i

add annotation i

add conductor damage curve i

add damage curve from relay library i

add generator loadability limit i

add picture i

add relay curves i

add shape i

add time difference sliders i

add transformer damage curve i

add transformer inrush curve i

add unstable power swing region i

close i

edit legend i

edit relay settings i

edit shifting factors i

options i

picture background i

rearrange captions i

remove all but 1st relay curve i

remove annotation i

remove fault results i

remove generator loadability limit i

remove picture i

remove relay or fuse curve i

remove shape i

remove time difference slider i

show relay operations for 1 fault i

show relay operations for all faults i

show relay test values i

show TTY window i

trial relay adjustment i

D

Damage Curve

add from library i

edit parameters in Curves Window i

Data Browser i

area data i

customization i

report i

scale load and generation i

zone data i

Data mapping script i

Dates

in/out of service i

DC Line

contribution to short circuit current i

data in text data file i

dialog box and data i

DCB (Directional Comparison Blocking) i

Default Relay Pickup Time i

Definite-Time Overcurrent Relay i

Delete

all circuit breakers i

all in area or zone i

all inside a region i

all outside a region i

network elements i

relays or relay groups i

Delete All Relays i

Device palette

Insert tap node i

new 2-winding transformer i

new 3-winding transformer i

new dc line i

new line i

new load i

new phase shifter i

new series capacitor/reactor i

new shunt i

new switch i

new switched shunt i

Show/Hide i

Device Palette

new synchronous machine i

Differential Relay See Line Differential Relay

Disguise File Identity i

Distance Ground Relay

dialog box and data i

Distance Phase Relay

dialog box parameters i

Distance Relay i

dynamic characteristics i

line-impedance percentages i

manufacturer specific models i

new phase and ground relay in relay group i

view characteristics i

Distance Relay Window i

add annotation i

add generator loadability limit i

add picture i

add relay characteristics i

add remote branch impedances i

add shape i

add unstable power swing region i

close i

display load region i

edit generator loadability limit i

edit relay settings i

find origin i

find origin of 2nd relay i

find origin of 3rd relay i

grid on/off i

options i

print i

rearrange captions i

remove all but 1st relay i

remove annotation i

remove generator loadability limit i

remove load region i

remove picture i

remove remote branch impedances i

remove shape i

remove unstable power swing region i

show relay operations for 1 fault i

show relay operations for all faults i

show TTY window i

DistriView Substation Group Number i

Doble SS1 Formatted Relay Test File i

Drag and Drop

device palette i

to create new 2-winding transformer i

to create new 3-winding transformer i

to create new dc line i

to create new generator i

to create new line i

to create new load i

to create new phase shifter i

to create new series capacitor i

to create new shunt i

to create new switch i

to create new switched shunt i

to create new voltage controlled current source i

to merge buses i

Dual Pilot

max number of time steps i

tag i

DUTT (Direct Underreach Transfer Trip) i

Dynamic characteristics See Distance relay | Dynamic characteristics

Dynamic Reactive Current Control of converter-interfaced resource i

E

ENOSERV i

ENOSERV PowerBase i

Enterprise Module

apply configuration i

commit i

dashboard i

data sync wizard i

get latest version i

setup i

version history i

Equivalent Branch Color Code i

Exit Program i

Export

breaker data i

graphical data from Curves Window i

graphical data from Main Window i

graphical data in DS Relays Window i

network data i

relay data i

Export network data

to ANAFAS i

to ANAREDE format i

to GE PSLF format i

to PSS/E format i

F

Fault See Short Circuit

Fault Browser in Curves Window i

Fault Locator

SEL event file i

Fault MVA

definition i

Fault Specification File i

format i

File

add i

case builder i

merge i

File

backup i

binary data files i

change files i

output files i

PowerScript file i

previous curve collection files i

report files i

text data file i

Windows metafile i

File

line table files i

File

relay data file sample i

File

change files i

File Comments i

Find Annotation in Main Window i

Find Annotation on one-line-diagram i

Find Bus

by name i

by number i

invisible bus i

Find PowerCalc Worksheet on one-line diagram i

Flat Start See Prefault Voltage Profile | Assumed Flat Option

FLT file See Fault Specification File

Font Size

Curves Window i

DS Relays Window i

Main Window i

Time-Distance Window i

Frequency

system i

Fuse

add fuse curve i

change size with Trial Adjustment command i

dialog box and data i

new in relay group i

G

GE Format

compatibility with i

export to i

Generating Unit

dialog box and data i

Generator

current limited i

data in text data file i

delete i

dialog box and data i

model i

referene angle set i

scale output i

Generator Loadability Limit i

remove from Curves Window i

Go back i

Go To End Bus i

GPS Coordinates i

Graphics

acquire from another file i

Grid On/Off i

Ground Current Calculator i

Grounding impedance i

H

Hardware Requirement i

Help

on-line help i

Hide Bus

selected bus i

Hide Equipment

by region i

Holding Tank For Relays i

I

IEEE 1584-2011 Standard i

IEEE 1584-2018 Standard i

Ignore

instantaneous settings i

phase shift i

Impedance Correction Table i

Impedances on One-Line Diagram i

Import

network data i

relay data from .RAT file i

Import relay data files i

Import Relay Data wizard i

In/Out Service Dates i

project management i

Insert Line Kink i

Insert Tap Bus i

Instantaneous Overcurrent Relay i

Interrupting Time i

J

Journal

export report to CSV file i

Junction Bus in Time-Distance Window i

K

Key

update memory i

Keyboard Accelerators i

kV Color Code i

L

Legend

edit parameters of i

Length Unit Preference i

Library

distance relay i

overcurrent relay i

overcurrent relays, fuses & reclosers i

Library Directory i

managing i

Line See Transmission Line

Line Capacitance Emulation i

Line Differential Relay

dialog box and data i

Line End/Out Fault Summary i

Line Fault Clearing Summary i

Line Fault Summary i

Line Table File i

Line with Multiple Sections i

Link to ASPEN Relay Database i

Link to setting file i

Load

data in text data file i

delete i

dialog box and data i

model i

new i

scaling i

Load Region on DS Relays Window i

Load Tap Changer

2-winding transformer i

3-winding transformer i

reset center position i

specifying parameters for i

Load Unit

dialog box and data i

Lock One-Line Graphics From Being Modified i

Logic Schemes i

creation and editing i

DCB i

DUTT i

POTT i

POTT-PUTT i

PUTT i

trip logic equation syntax i

LTC See Load Tap Changer

M

Macro See PowerScript

Manufacturer Specific Distance Relay Models i

Merge Buses i

Merge File with Common Base i

MOV simulation

acceleration factor i

turn on/off i

Multi-Section Line i

fault simulation on i

navigation i

Multi-Section Lines i

Mutual Coupling Pair

copy i

create i

data in text data file i

delete i

dialog box and data i

edit parameters of i

paste i

threshold i

Mutual Coupling Threshold i

Mutual Group

edit parameters of i

MVA Base

2-winding transformer i

phase shifter i

substation data interface i

system i

N

Network

anomalies checking i

export data i

hide equipment by area or zone i

properties i

show equipment by area or zone i

show equipment by region i

show/hide elements i

Network Data

importing i

Network Equivalent See Boundary Equivalent

Network Modeling i

Neutral Current

in phasor probe i

Nominal kV of Bus

change i

Note See Annotation

O

OC Curves Window See Curves Window

OLX text data file i

OLXAPI i

OLXAPI Dashboard i

One-Line Diagram

creation i

scale/shift i

view solution on i

On-Line Help i

Operating System Supported i

Options

diagram i

DS Relays Window i

faults i

network i

OC Curves Window i

relays i

X/R ratio i

Outage List i

Output File i

Overcurrent Ground Relay

dialog box and data i

Overcurrent Phase Relay

dialog box and data i

Overcurrent Relay i

extrapolate curve i

new phase and ground relay in relay group i

time dial calculator i

view curve i

P

Package-A and Package-B relays i

Palette See Device palette

Parameters for New Objects i

Paste data from a spreadsheet i

Paste from Clipboard

equipment and relays in region i

network data i

relay data i

using drag/drop palette i

Phase Shift

ignore option i

Phase Shifter

dialog box and data i

model i

Phase-Open Fault i

Phasor Probe i

Picture

add to Curves Window i

remove from Curves Window i

remove from Distance Relay Window i

Place Buses i

Plain One-Line Diagram i

POTT (Permissive Overreach Transfer Trip ) i

POTT-PUTT i

Power Factor Angle i

PowerBase i

POWERBASE i

PowerCalc Worksheet i

add to one-line diagram i

delete i

find on one-line diagram i

functions i

PowerScript

custom user-defined commands i

Dashboard i

PRC-023-3 Standard

checking a DS relay i

checking an OC relay i

checking multiple OC and DS relays i

PRC-025-1 Standard

checking a DS relay i

checking an OC relay i

PRC-026-1 Standard

checking a DS relay i

checking an OC relay i

checking multiple OC and DS relays i

PRC-027 Standard

checking relay operations i

checking relay settings i

detecting changes in fault current i

Prefault Voltage Profile

assumed flat option i

choosing i

from a linear network solution option i

from a power flow solution option i

Previous Curve Collection

open i

rename and remove i

Previous Time-Distance Diagram

open i

rename and remove i

Previous Time-Distance Diagram File

open i

save a diagram i

Print

DS Relays Window i

graph in OC Curves Window i

one-line diagram i

overcurrent relay curves i

selected text i

Printer

setup i

Project Management

in/out service dates and tags i

Properties

network i

relay group i

Protective-Level Current of Series Capacitors i

PTI Format

compatibility with i

PTI PSS/E Format

export to i

Put Equipment in Service i

PUTT (Permissive Underreach Transfer Trip ) i

R

Rearrange Captions

in Curves Window i

in distance relay window i

in DS Relays Window i

Recloser

dialog box and data i

new in relay group i

Reclosing Logic and Interval for Lines and Switches i

Reference Angle of Generators i

Relay

take on/off-line i

Relay Checking Parameters and Options i

Relay Coordination Checking

latest method using stepped events i

legacy method of OC/OC checking i

legacy multi-point checking method i

legacy primary/backup using coordinating pairs i

line and transformer outages i

outage of 3 strongest sources at each line terminal i

outage of mutual-coupled lines i

pilot communication outages i

recloser/relay checking i

Relay Coordination Pair

form i

Relay Curve

add to OC Curves Window i

remove all from Distance Relay Window i

remove from Curves Window i

remove relay or fuse curve i

start a one time pickup i

Relay Curve Library Name

reset i

Relay Data File i

exporting i

format information (legacy) i

importing i

sample i

Relay Data Import Sources i

Relay Database i

Relay Database Linkage i

initialize relay database template i

retrieve relay parameters from database i

Relay Group

add or remove coordinating pairs i

copy a relay from i

copy all relays in group i

delete i

importing a relay into i

new i

pasting a relay into i

Relay Loadability Checking i

Relay on Remote Bus

add to DS Relays Window i

Relay Operating Time

definition i

Relay Operations for 1 Fault

show in DS Relays Window i

show in OC Curves Window i

Relay Operations for All Faults

show in DS Relays Window i

show in OC Curves Window i

Relay Packages A and B i

Relay Parameter Checking

legacy OC instantaneous unit i

legacy OC minimum pickup i

new command for OC and DS relays i

Relay Performance during Stable Power Swing i

Relay Pickup Time i

Relay Setting

edit in Curves Window i

edit in DS Relays Window i

Relay Test File i

comma delimited file i

COMTRADE format i

Doble SS1 format i

Relay Test Point i

Relay Test Values,Show i

Reload File from Disk i

Remote Branch Impedances

add to distance relay window i

remove from DS Relays Window i

Remove Tap Bus i

Report

network data from Browser i

relay data i

relay data from Browser i

Report File i

Reset text position i

R-Only Network i

Run Configuration Program i

Run Distance Relay Editor i

Run Overcurrent Curve Editor i

S

Save Copy for New Study Date i

Scale/Shift One-Line Diagram i

Script See PowerScript

Scrolling

with mouse wheel i

with scrollbars i

Search Network i

Second Relay Origin

find origin in distance relay window i

SEL-5010 Relay Data

import from i

SEL-5030 Relay Data

export to i

import from i

Series Capacitor

change from line i

model i

Series Capacitor/Reactor

new i

Series Reactor

model i

Shape

add to Curves Window i

add to Distance Relay Window i

remove from Curves Window i

remove from Distance Relay Window i

Shifting Factor i

Short Circuit

batch fault simulation i

bus fault summary i

bus-to-bus fault i

classical faults i

close-in fault in front of a relay i

cross-country fault i

ground current calculator i

intermediate fault i

intermediate faults at regular inteval i

line end/out fault summary i

line fault summary i

line-end fault i

options i

phase-open fault i

prefault voltage options i

printing solution report i

simultaneous faults i

solution display options i

solution report in text i

view voltage-sag results i

Short Circuit Solution

algorithm used i

text report format i

Shortcuts

for the dialog boxes i

for the distance relay window i

for the keyboard i

for the main window i

for the overcurrent relay window i

for the TTY window i

main window toolbar i

Show Bus

by region i

in area or zone i

Show Equipment

by region i

Show/Hide Area i

Shunt

currents i

data in text data file i

delete i

dialog box and data i

model i

Shunt Unit

dialog box and data i

Signal only flag i

Simultaneous Fault i

Single Pilot

allow single branch outages i

tag i

SIR See Source Impedance Ratio

Size Limitations i

Slack Bus for Power Flow i

area export control i

in Data Browser i

MW limits i

Snap to State Plane Coordinates i

Solar Plant

modeled as Converter-Interfaced Resource i

Solution On One-Line i

Source Impedance Ratio

calculator i

Sparse Matrix and Vector Methods i

Split Bus i

STATCOM

modeled as a voltage controlled current source i

STATCOM Model i

State Plane Coordinates

re-position buses using i

State Plane Coordinates for Bus i

Statistics i

Stepped-Event Analysis

line fault clearing summary i

multiple user-defined event i

single user-defined event i

view results i

Store setting to ASPEN Relay Database i

String Delimiter for Text Data Files i

Stub Fault Simulation i

Stub Line

definition i

Substation Data Interface i

Substation Group Number i

SVD See Switched Shunt

Switch

data in text data file i

dialog box and data i

resistance and reactance i

set all to normal state i

toggle i

Switched Shunt

data in text data file i

dialog box and data i

model i

System Base MVA i

System Frequency i

T

T Circuit Model of 3-Winding Tansformer i

Tags

apply i

browser i

project management i

relay package A and B i

remove i

rename i

special color i

view on Main Window i

Take Out of Service i

Tap Bus i

insert into a line i

remove from a line i

show or hide bus name on one-line i

Tap Bus of Three Terminal Line i

Tapped Line

definition i

relay checking i

Tapped Transformer

definition i

relay checking i

Tertiary Current

displayed by phasor probe i

in solution report in text i

Text Data File i

comments i

format information i

open i

Text Orientation Option i

Text Report Viewer i

commands in i

index i

open file i

print i

save case i

Third Relay Origin

find origin in distance relay window i

Three Terminal Line

checking relay settings i

end to end testing i

tap bus attribute i

Three Winding Transformer

change from T model i

dialog box and data i

tertiary current in phasor probe i

tertiary current in text report i

Tie Line

flow in calculating net MW export i

include in data export i

meter location for Power Flow i

show list for an area i

show on 1-line i

Tier

extent of fault solution in report i

extent of short circuit solution display on 1-line i

for stepped-event simulation i

in voltage-sag report i

Time Dial Calculator i

Time Difference Sliders

add to Curves Window i

remove from Curves Window i

Time Unit Preference i

Time-Distance Diagram i

Time-Distance Window i

add branch to diagram i

add monitor relay to diagram i

add sliders i

close i

edit annotation i

edit monitored relay i

junction bus i

open i

options i

print i

remove annotation i

remove branch to the right i

remove first branch i

remove slider i

show curves i

Toolbar i

Transformer See also Two-Winding Transformer and Three-Winding Transformer

2-winding configurations i

2-winding model i

3-leg core i

3-winding configurations i

magnetizing impedance i

models for 2- and 3-winding i

neutral current in phasor probe i

new 2-winding i

reset taps to nominal i

symbol, American or European i

tap voltages i

Transformer damage curve

edit parameters of i

Transformer Damage Curve

add i

Transformer Inrush Curve

add i

Transmission Line

change to series capacitor/reactor i

data in text data file i

description of faults i

dialog box and data i

model i

ratings in A or MVA i

Trial Relay Adjustment i

TTY Window i

clear contents of i

close i

copy selected text to clipboard i

find text i

hyperlink i

print selected text i

save selected text to file i

select all text i

select font and size of text i

view in DS Relays Window i

view in main window i

view in overcurrent relay window i

Tutorial

Curve Editor and Distance Relay Editor i

OneLiner i

Two Winding Transformer

models i

new i

Type-3 Wind Plant

dialog box and data i

modeled with no MW injection i

QandA i

U

UDF i

Undo i

button on toolbar i

Unstable Power Swing Region

for distance relays i

for overcurrent relays i

User Defined Data Fields i

V

View

areas, tie lines on one-line i

branch names on one-line diagram i

distance relay characteristics i

impedances on one-line diagram i

overcurrent relay curves i

phasors i

plain one-line diagram i

solution on one-line diagram i

toolbar on Main Window i

TTY Window i

Voltage Controlled Current Source

dialog box and data i

fault simulation option i

for modeling STATCOM i

modeled with no MW injection i

Voltage Controlled Overcurrent Relay i

Voltage Relay

dialog box and data i

Voltage Restrained Overcurrent Relay i

Voltage Sag Analysis i

with stepped-event clearing time i

VSC DC Line Terminals i

W

Wind Plant Type 4

modeled as Converter-Interfaced Resource i

Wind Plant Type-3 i

Windows Metafile i

X

X/R Ratio

ANSI i

complex versus ANSI i

in bus fault summary i

in fault summary i

typical values i

XML formatted text data file i

X-Only Network i

Z

Z2 Equals Z1 Assumption i

Zero-Sequence Mutual Coupling See Mutual Coupling Pair

Zigzag-delta 2-Winding Transformer i

Zigzag-wye 2-Winding Transformer i

Zigzag-wye-delta 3-winding transformer i

Zigzag-zigzag-wye 3-winding transformer i

Zone

data in text data file i

renumber i

Zone Data Modification i

Zone of a Bus

change i

Zoom Slider

distance relay window i

main window i